TY - JOUR TI - Estimation of the Concentration of Low-Density Lipoprotein Cholesterol in Plasma, Without Use of the Preparative Ultracentrifuge AU - William T. Friedewald AU - Robert I. Levy AU - Donald S. Fredrickson PY - 1972 JO - Clinical Chemistry DO - 10.1093/clinchem/18.6.499 UR - https://doi.org/10.1093/clinchem/18.6.499 AB - Abstract A method for estimating the cholesterol content of the serum low-density lipoprotein fraction (Sf0-20) is presented. The method involves measurements of fasting plasma total cholesterol, triglyceride, and high-density lipoprotein cholesterol concentrations, none of which requires the use of the preparative ultracentrifuge. Comparison of this suggested procedure with the more direct procedure, in which the ultracentrifuge is used, yielded correlation coefficients of .94 to .99, depending on the patient population compared. ER -